Inductive positioning system PMI104-F90-IU-V1

PMI104-F90-IU-V1
  • Analog output 0 V ... 10 V/4 mA ... 20 mA
  • Measuring range 0 ... 104 mm

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Datasheet excerpt: Technical data of  PMI104-F90-IU-V1

General specifications
Switching element functionanalog, current or voltage output
Object distance0.5 ... 3 mm , recommended: 2 mm
Measurement range0 ... 104 mm
Linearity range1 ... 103 mm
Nominal ratings
Operating voltage18 ... 30 V DC
Reverse polarity protectionreverse polarity protected
Linearity errorwithin measuring range: ± 0.8 mm
within linearity range: ± 0.4 mm
Repeat accuracy± 0.1 mm
Resolution125 µm
Temperature drift± 0.5 mm (-25 °C ... 70 °C)
No-load supply current≤ 40 mA
Operating voltage indicatorLED green
Functional safety related parameters
MTTFd320 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Analog output
Output type1 current output: 4 ... 20 mA
1 voltage output: 0 ... 10 V
Load resistorcurrent output: ≤ 400 Ω
voltage output: ≥ 1000 Ω
Short-circuit protectionvoltage output: pulsing
Compliance with standards and directives
Standard conformity
StandardsEN 60947-5-2:2007
IEC 60947-5-2:2007
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
UL approvalcULus Listed, General Purpose, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection type4-pin, M12 x 1 connector
Degree of protectionIP67
Material
HousingABS
Targetmild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Dimensions
Height41 mm
Width23 mm
Length126 mm

Classifications

SystemClasscode
ECLASS 13.027274004
ECLASS 12.027274004
ECLASS 11.027270702
ECLASS 10.0.127270702
ECLASS 9.027270702
ECLASS 8.027270702
ECLASS 5.127270702
ETIM 9.0EC001852
ETIM 8.0EC001852
ETIM 7.0EC001852
ETIM 6.0EC001852
ETIM 5.0EC001852
UNSPSC 12.139121550

Details: PMI104-F90-IU-V1

CAD+CAE: PMI104-F90-IU-V1

CADFile TypeFile Size
CAD 3-D / CAD 3-DSTP538 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: PMI104-F90-IU-V1

CertificatesFile TypeFile Size
Canada USA UL Ordinary LocationPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1218 KB
UK Declaration of Conformity (P+F)PDF1284 KB

Associated Products: PMI104-F90-IU-V1

Accessories

Female cordset single-ended M12 straight A-coded, 4-pin, PVC cable greyfa
Damping element for sensors of type F90, F112, and F166; side holefa
Mounting bracket for mounting of F90 sensorsfa
Damping element for sensors of type F90, F112, and F166; front holefa