Bus carrier with bus PCB for 35 mm DIN mounting rail, height 7.5 mm, Provides DC supply voltage and the bus connection to all equipped SC-System modules, Standard length 500 mm (19.7 inch), simple to customize to application space, Eliminates daisy-chainspa
Fan-shaped detection field with up to 12 beams, Closing safety monitoring over the complete door width, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: relay, 1 NO, Connection: 5 m fixed cablefa
Version with E1 approval, Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Automatic drift compensation, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: AMP connector 6-pin , 2 m fixed cablefa
Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Preset version, Version with switches determine sensing field, Automatic drift compensation, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: AMP connector 6-pin , 2 m fixed cablefa
Version with E1 approval, Fan-shaped detection field with up to 12 beams, Adjustable detection fields for different door widths, Automatic drift compensation, Version with test input, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 12 ... 38 V DC, Signal output: 1 PNP, short-circuit protected, reverse polarity protected, open collector, Connection: Fixed cable 3 m, halogen-free, with ferrite corefa
13306-13310/21387Ilość elementów na stronie:
Produkty wycofane z produkcji
W wyniku Twojego zapytania otrzymano 12340 wynik (-i, -ów)
Niedostępne w sprzedaży: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niedostępne w sprzedaży: 1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters, current and voltage sources, Current and voltage output, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 19 ... 90 V DC / 48 ... 253 V AC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA (current source), Signal [2]: 1 x 0/2 ... 10 Vpa
Niedostępne w sprzedaży: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Niedostępne w sprzedaży: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Niedostępne w sprzedaży: Vehicle holder (passive, Non-Ex) for Tab-Ex 02 DZ1pa