Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Inductive sensor NCN4-V3-N0-0,8M

NCN4-V3-N0-0,8M
  • 4 mm non-flush


NAMUR sensors must be operated with approved switch amplifiers. Please find suitable devices below:

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Dane techniczne  NCN4-V3-N0-0,8M

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance4 mm
Installationnon-flush
Assured operating distance0 ... 3.24 mm
Reduction factor rAl 0.3
Reduction factor rCu 0.2
Reduction factor r304 0.7
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 2000 Hz
Hysteresistyp. 5 %
Current consumption
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd1735 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Approvals and certificates
IECEx approval
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level DaIECEx PTB 11.0021X
Equipment protection level MbIECEx PTB 11.0021X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2032 X
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level DaPTB 00 ATEX 2032 X
UL approvalcULus Listed, General Purpose, Class 2 Power Source
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CML approvalon request
ANZEx19.3001X
Ambient conditions
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Mechanical specifications
Connection typecable
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Cable
Cable diameter2.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Core cross section0.14 mm2
Length0.8 m
Tightening torque, fastening screws≤ 0.4 Nm
Dimensions
Height10.2 mm
Width27.8 mm
Length16 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NCN4-V3-N0-0,8M

Documents: NCN4-V3-N0-0,8M

Instruction manualsTyp plikuRozmiar pliku
ИнструкцииPDF193 KB
Návod k poużitíPDF184 KB
Instruktions manualPDF182 KB
Instruction manualPDF184 KB
KasutusjuhendPDF177 KB
KäyttöohjePDF177 KB
Manuel d'instructionsPDF188 KB
BetriebsanleitungPDF185 KB
Οδηγίες χρήσηςPDF195 KB
HandleidingPDF185 KB
Instruction manual / BetriebsanleitungPDF182 KB
Használati útmutatóPDF188 KB
Manuale di istruzioniPDF186 KB
Lietošanas pamācībaPDF183 KB
Instrukciju vadovasPDF184 KB
Instrukcja obsługiPDF186 KB
Manual de instruçõesPDF188 KB
Manual de utilizarePDF188 KB
Návod na poużitiePDF186 KB
Navodila za uporaboPDF181 KB
Manual de instruccionesPDF188 KB
ManualPDF182 KB

Approvals+Certificates: NCN4-V3-N0-0,8M

CertificatesTyp plikuRozmiar pliku
Australia Test SafePDF6749 KB
Canada USA UL Hazardous LocationPDF412 KB
Canada USA UL Ordinary LocationPDF1806 KB
EU PTB ATEX ia 2G, 1G, 1D s. certificatePDF12357 KB
Japan CML Ex iaPDF468 KB
United Kingdom CML UKEX Category I M2 UKEX Category II 2 G UKEX Category II 1 D UKEX Category II 1 GPDF420 KB
Worldwide PTB IECEx iaLINK---
Control Drawings
Control drawing UL / Control drawing ULPDF294 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1248 KB
EU Declaration of Conformity (P+F)PDF1332 KB
EU Declaration of Conformity (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1329 KB
UK Declaration of Conformity (P+F)PDF1241 KB
UK Declaration of Conformity (P+F)PDF1303 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F)PDF1325 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU-Konformitäterklärung (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1333 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1330 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1328 KB
EU Declaration of Conformity (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1328 KB
EU Declaration of Conformity (P+F)PDF1329 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1327 KB
EU Declaration of Conformity (P+F)PDF1326 KB
EU Declaration of Conformity (P+F)PDF1329 KB

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont z technologią aktywnego ekranowania

Czujniki indukcyjne VariKont z technologią aktywnego ekranowania zapewniają duże odległości przełączania, niezależnie od warunków instalacji i otaczającego materiału. Skorzystaj z prostszej konstrukcji sprzętu i obniżonych kosztów!

Indukcyjne czujniki bezpieczeństwa SIL 2 PL d

Dzięki temu, że indukcyjne czujniki bezpieczeństwa SIL 2/PL d nie mają martwej strefy, przesyłanie danych może odbywać się bez minimalnej odległości między czujnikiem a obiektem docelowym. Odkryj ofertę zoptymalizowaną pod kątem wymagających środowisk.